Anton Paar MCR702 Rheometer

Anton Paar MCR702 Rheometer

  • Special accessories for DMA and DMTA measurements, rheo-optics, magneto- and electrorheology, interfacial rheology, UV curing and many other applications

  • Temperature range: –150 °C to 1000 °C

  • Torque range: 1 nNm to 230 nNm (rotation) and 0.5 nNm to 230 nNm (oscillation)
  • Angular velocity range: 0 rad/s to 314 rad/s
  • Angular frequency range: 10-7 rad/s to 628 rad/s
  • Angular deflection range: 0.05 µrad to ∞ (set value)

  • Normal force range: -50 N to 50 N
  • Magnetic field: 0 to 3 T
 Leica DMi8 Inverted Fluorescent Microscope

 Leica DMi8 Inverted Fluorescent Microscope

  • Options for transparent lighting: bright field, dark field and phase contrast
  • Fluorescence filter sets: DAPI, FITC and RHOD
  • Adjustment of viewing position (tile scanning or mark & find) and focus (extended depth of focus) during the image recording process
  • Time-lapse image capture series
RIGOL DP811A DC Power Supply

RIGOL DP811A DC Power Supply

  • 2 Ranges; total power up to 200W
  • Low Ripple Noise <350 uVrms/2mVpp
  • Fast transient response time: <50 us
  • Up to 10A or 40 V
  • OVP/OCP/OTP protection functions
  • Built in V, A, W measurements and waveform display
  • Support for output Delay, Analysis, Monitor, and Preset functions
  • 3.5 inch TFT Display
  • Connectivity including USB Host & Device, LAN, and Digital IO
Keysight Technologies 33210A Function/Arbitrary Waveform Generator

Keysight 33210A Function/Waveform Generator

  • 10 MHz Sine and Square waveforms

  • Pulse, Ramp, Triangle, Noise, and DC waveforms
  • Optional 14-bit, 50 MSa/s, 8K point Arbitrary Waveform Generator
  • AM, FM, and PWM modulation types
  • Linear & logarithmic sweeps and burst operation
  • 10 mVpp to 10 Vpp amplitude range
  • Graph mode for visual verification of signal settings
  • Connect via USB, GPIB and LAN
  • Fully compliant to LXI Class C specification
  • Power Rating: 100-240 V @ 50/60 Hz, 100-120 V @ 400 Hz
QSONICA Sonicator

QSONICA Sonicator

  • Power Rating: 500 Watts
  • Frequency: 20 kHz
  • Programmable Timer: 10 Hours
  • Adjustable Pulse On/Off: 1 Second to 1 Minute
  • Dimensions: 8" W x 15.25" L x 8.5" H
  • Voltage: 110V, 50/60Hz
Hach pH HQ440D Benchtop Meter

Hach pH HQ440D Benchtop Meter

  • pH measurement range: 0 to 14 pH
  • pH Resolution: 0.001/0.01/0.1 pH
  • Operating temperature range: 0 °C to 60 °C 
Chemat Technology Spin Coater KW-4A

Chemat Technology Spin Coater KW-4A

  • Power: 115 VAC, 60 Hz, 1 Amp 220 VAC, 50 Hz, 1 Amp
  • Stage 1: 500 rpm to 2500 rpm, 2 to 18 Seconds (2-Stage Spinning)
  • Stage 2: 1000 rpm to 8000 rpm, 3 to 60 Seconds
  • Vacuum:  2.1 CFM
  • Speed Stability:  <1%
  • Front Panel Controls: Digital Readout in Speed 1000 rpm
  • Timer Controls: Stage I and Stage II
  • Speed Controls: Stage I and Stage II
  • Control switch
  • Vacuum switch
  • Power switch
  • Start switch
  • Dimension (D x W x H):10 x 8.5 x 8.5 in. (25.4 x 21.5 x 21.5 cm)
  • Weight: 15 lbs (6.8 kg)
Shaker

Fisherbrand™ Variable Speed Mini Vortex Mixer 

  • Speed: 500 rpm to 2800 rpm
  • Dimension: 3.8 in. x 3.8 in. x 4.2 in.
CAT X 1000 UNIDrive Homogenizer

CAT X 1000 UNIDrive Homogenizer

  • Power supply: 115VAC 60Hz
  • Motor power: 1050W 
  • Speed range: 4.000 rpm  to 33.000 rpm
ECLIPSE Ti2-A Inverted Microscope

ECLIPSE Ti2-A Inverted Microscope

  • Operating temperature: 0℃ to 40℃
  • Operating humidity: 60% RH max. (at 40℃, no condensation)
The Trek model 10/10B-HS High-voltage Power Amplifier

High-voltage Power Amplifier

  • Operation temperature: 0 °C to 40 °C
  • Relative humidity: to 85%, non-condensing

  • Output voltage range: 0 to ±10 kV DC or peak AC

  • Output current range: 0 to ±10 mA DC or ±40 mA peak for 1 ms

  • Gain: 1000 V/V

  • Slew rate: Greater than 700 V/μs (10% to 90%, typical)

  • Large signal bandwidth: DC to greater than 19.5 kHz
Transmission Flow Cell (Model FC 285)

Transmission Flow Cell (Model FC 285)

  • Dimension: 2.0” × 0.5” × 0.10” 
  • Maximum flow rate: 3.5 mL/min
Quartz Crystal Microbalance QCM-D with Dissipation Module

Quartz Crystal Microbalance QCM-D with Dissipation Module

  • Working temperature: 0 °C to 50 °C

  • Frequency range: 1 MHz to 50 MHz

  • Maximum mass sensitivity in liquid: ~ 1 ng/cm2 (10 pg/mm2)
  • Maximum dissipation sensitivity in liquid: ~ 0.1 x 10-6

  • Typical noise: [Liquid: 1 Hz peak to peak (RMS)] - [Air: 0.1 Hz peak to peak (RMS)]

  • Time resolution: ~600 ms
  • Input Voltage: 5 VDC

  • Max current: 200 mA @ 5 VDC
Tweez 305 Turn-key Optical Tweezer System

Tweez 305 Turn-key Optical Tweezer System

  • Optical traps: 2500 time-multiplexed

  • Trap-to-trap switching rate: 100 kHz

  • Working field: 100 μm x 100 μm (with 60x microscope objective)

  • Camera: fast, high sensitivity 4 Megapixel (2048 x 2048) monochrome/color image sensor with pixel size 5.5 μm

  • Laser: 5 W CW, 1064 nm

  • Synchronization with external equipment: dedicated high speed Sync and Expansion ports

  • Power requirements: 100 – 230 V, 50 / 60 Hz